Brand: Honeywell Description: Safe Digital Output Module Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 6 Payment Term: T/T Shipping Port: Shenzhen Honeywell FC-SDO-0424 has 4 separate channels and direct integration with solenoid operators. It has a Fault notification system as well as built-in diagnostics and redundancy so that the output remains fault-safe, this makes it an attractive choice for process control, emergency shutdown systems and other applications.
Manufacture |
Honeywell |
Model Number |
FC-SDO-0424 |
Ordering Number |
FC-SDO-0424 |
Catalog |
- |
Country Of Origin |
United States (US) |
HS CODE |
8471800000 |
Dimension |
18*8*6cm |
Weight |
0.6kg |
Product Features
Honeywell FC-SDO-0424 supports fail-safe functionality, automatically switching to a pre-set safe state in the event of a fault.
Honeywell FC-SDO-0424 incorporates intrinsic short-circuit, overload and overheat security having an answer amount of ≤5ms that being said produce a computerized rehabilitation.
Honeywell FC-SDO-0424 features IP65/IP67 protection rating and operates in an extended temperature range (-40°C to +85°C).
Honeywell FC-SDO-0424 supports the Modbus RTU protocol and is compatible with mainstream industrial control systems. It supports DIN rail mounting and can be seamlessly integrated with Honeywell FC series controllers.
Product Using Principle
Honeywell FC-SDO-0424 receives digital commands from a PLC or controller.
It converts digital signals into analog or switch signals to drive solid-state relays or mechanical contacts.
It monitors the output circuit status in real time and immediately triggers protection and switches to a safe state if a fault is detected.
It transmits status information back to the control system via Modbus RTU to achieve closed-loop monitoring.
Product Application
In the feed stage of a chemical reactor, Honeywell FC-SDO-0424 receives commands from the DCS system to activate the solenoid valve of the pneumatic valve, thereby controlling the feed rate. When the reaction temperature exceeds the threshold, the system closes the feed valve via the module to prevent overheating hazards.
In oil transmission pipelines, Honeywell FC-SDO-0424 controls the start/stop and switching of pump units. When the main pump pressure is insufficient, the system activates the standby pump via the module to ensure stable pipeline pressure.
In high-risk locations such as oil platforms and chemical plants, the ESD system must immediately cut off power to all critical equipment in the event of leaks, overpressure, or other emergencies. As an execution-level module, Honeywell FC-SDO-0424 receives commands from the ESD controller to activate the emergency stop relays of the equipment.
When a fire alarm detects smoke or high temperatures, it coordinates with fire protection equipment via the FC-SDO-0424, such as activating exhaust fans, closing fire dampers, and cutting off non-fire protection power supplies.