Brand: Honeywell Description:MC-TAOY22 ANALOG OUTPUT Condition:New Certificate:COO TEST REPORT WARRANTY LETTER Warranty:1 year Inventory Qty:25 Payment term:T/T Shipping Port:ShenZhen Honeywell MC-TAOY22 has stable electrical characteristics, wide application range, adaptability to complex industrial production environments, high measurement accuracy, support for a variety of communication interfaces, built-in intelligent alarm and diagnosis, high reliability, good safety, easy installation, commissioning and maintenance.
Manufacture |
Honeywell |
Model Number |
MC-TAOY22 |
Ordering Number |
51204172-175 |
Catalog |
TDC 3000 |
Country Of Origin |
United States (US) |
HS CODE |
8517795000 |
Dimension |
30.8 *12.1 * 5.5 cm |
Packing Dimension |
35*15*8cm |
Weight |
0.6kg
|
Technical Data Sheet
Physical Characteristics: The metal shell of Honeywell MC-TAOY22 is sturdy and durable, with excellent anti-electromagnetic interference ability, protection level of [specific protection level], and can resist dust, moisture and a certain degree of physical impact. The size is calculated as [length × width × height], which is small and exquisite, easy to install in a small room, and light weight of about [X] kg, which is convenient for installers to operate and integrate equipment.
Electrical characteristics: Honeywell MC--TAOY22 51204172-175 has a wide operating voltage range, [lower limit]~[upper limit] volts when working, and can operate efficiently under different industrial power supply conditions. Its power consumption during normal operation is relatively low, about [X] watts, which plays a huge role in reducing total energy consumption and improving energy efficiency.
Performance indicators: High signal processing accuracy, the measurement accuracy of analog input signals is ± [accuracy], and it has the ability to measure and finely convert subtle signal changes. The data transmission rate is relatively fast, which is [transmission rate], ensuring that the data transmitted between the industrial computer is timely and accurate, and meeting the best requirements for real-time control.
Functional characteristics
Various types of signal processing: Honeywell MC-TAOY22 Various input signals, thermocouples, thermal resistors, voltages, and continuous signals all have standard output signals, which are convenient for integration with other automation equipment to comprehensively monitor and control various parameters in industrial operations.
Intelligent diagnostic function: Honeywell MC-TAOY22 monitors the operating status of the equipment and the quality of input and output signals in real time through the built-in intelligent diagnostic module. When the system encounters abnormal conditions (such as signal crossing the boundary, equipment failure, etc.), an alarm is immediately issued, and combined with detailed diagnostic information, it helps maintenance personnel quickly locate the cause, shorten downtime, and improve efficiency.
Rich communication interface: Provides multiple communication interfaces such as RS485 and Ethernet, supports mainstream industrial communication protocols such as Modbus and TCP/IP, and can be easily installed in complex industrial automation networks, and achieves seamless communication and data transmission with the host computer, PLC or other intelligent devices to build an efficient distributed control network.
Installation and debugging
Installation environment requirements: Honeywell MC-TAOY22 should be installed in a dry and well-ventilated place, away from strong electromagnetic interference sources such as large motors and transformers. To ensure the normal operation of the device and the expected service life, the temperature should be maintained between [minimum temperature] and [maximum temperature] during the operation of the device, and the relative humidity should be between [minimum humidity] and [maximum humidity].
Installation precautions: Honeywell MC-TAOY22 Install according to the installation manual, firmly fix the device on the installation plane, and ensure stable and horizontal placement. When connecting the power cord, it must be strictly in accordance with the electrical wiring diagram, pay attention to polarity and tightening, and prevent small problems from causing short circuits or open circuits. When connecting the signal line, ensure that the wiring is complete and reliable to avoid abnormal signal transmission.
Debugging steps: Honeywell MC-TAOY22 First use professional debugging software or tools to initialize the device, set communication parameters such as baud rate, IP address, signal range, sampling frequency, etc. Then simulate the signal source or connect the actual sensor to fully test the signal acquisition, processing, conversion and signal transmission functions of the device. During the test, pay attention to the operating status and data output of the equipment, and consider adjusting its parameters according to the circuit interaction response until the equipment runs stably and reaches the expected performance target.
Maintenance and care
Irregular cleaning: Clean the surface of the equipment at least once a month, and use a clean soft cloth to remove dust and dirt on the surface to check whether it is neat and tidy. At the same time, check whether the heat dissipation holes of the equipment are blocked. If there is a blockage, it should be cleaned in time to avoid affecting the performance.
Connection inspection: Perform a comprehensive inspection of the equipment terminals every quarter to check whether there is looseness, oxidation or corrosion. If there is a terminal problem, it should be handled immediately to ensure the reliability and stability of the wiring, so that the signal transmission is not interrupted or the equipment is damaged due to poor wiring. Instruments used for precision calibration equipment should be calibrated according to standard protocols at least once a year to maintain high accuracy. The calibration data and clearing records should be recorded throughout the calibration process so that the equipment can be evaluated and tracked afterwards.
Internal inspection
Every two years, professional technicians open the equipment casing and conduct a comprehensive inspection of the internal electronic components, circuit boards, etc. to check whether there is aging, cold soldering or damage. Maintenance refers to the performance or warranty inspection of the central part. If there is a problem, it must be repaired or replaced quickly. Clean the inside of the equipment and remove dust to provide a good environment for the equipment and ensure the normal and continuous operation of the equipment. By following these technical documents, users can take advantage of the performance advantages of Honeywell MC-TAOY22 to ensure the normal operation of the industrial automation system, optimize production efficiency and product quality, and extend the service life of the equipment.