Brand: Epro Description: Mounting Frame Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 1 Payment Term: T/T Shipping Port: Shenzhen The EPRO MMS6352 is a dual-channel speed/phase monitoring module with Hall-effect sensor compatibility, redundant 24V DC supply, and self-diagnostic functions for turbine and industrial machinery synchronization.
Manufacture |
Epro |
Model Number |
MMS6352 |
Country Of Origin |
Germany |
HS CODE |
9032900090 |
Dimension |
10*16*5cm |
Packing Dimension |
12*18*7cm |
Weight |
0.2kg |
Technical Parameters
Redundant Power Input: Supports dual 18–31.2V DC power sources with diode isolation.
Sensor Compatibility: processing pulse frequencies up to 16kHz (0–65,535 RPM).
Certifications: Complies with IEC 62443and SIL 2 safety standards .
Operating Environment
Industry-Specific DurabilityThe EPRO MMS6352 is designed for use in demanding industries, featuring a robust, IP-rated housing that resists dust, moisture, and corrosive elements. Due to its temperature range of -20°C to +80°C, it can be reliably used, especially in industries like power generation, oil refineries, and gas compressor stations.
Critical Machinery Monitoring: Tailored for turbines, generators, and high-speed compressors, the EPRO MMS6352 provides continuous overspeed protection to applications with rotational speed stability requirements.
Key Features
Dual-Channel Redundancy: The EPRO MMS6352 provides dual independent speed measurement channels, enhancing safety by cross-validating data to prevent false trips. Its 4–20mA analog output integrates seamlessly with DCS/PLC systems like Emerson DeltaV and Ovation.
Self-Testing & Diagnostics: Built-in fault detection circuits automatically validate sensor integrity and module health, triggering a 0mA output or alarm if anomalies are detected, ensuring fail-safe operation.
Compatible Equipment
Sensor Integration: Works with EPRO’s PR642x series eddy current sensors for precise non-contact speed measurement, supporting a wide RPM range (0–65,535).
System Connectivity: Supports Modbus and RS232 protocols for real-time data transmission to SCADA networks, while buffered voltage outputs (2–10V) enable local diagnostics.