Brand: EPRO Description: 8mm Eddy Current Sensor Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 1 Payment Term: T/T Shipping Port: Shenzhen The EPRO PR6423/00R-031, developed by Emerson, is a high-precision eddy current sensor designed for industrial machinery monitoring, offering reliable vibration and displacement measurements in hazardous environments with Eex ib IIC T6/T4 explosion-proof certification and compliance with API 670 standards.
Manufacture |
EPRO |
Model Number |
PR6423/00R-031 |
Country Of Origin |
Germany |
HS CODE |
9031809090 |
Dimension |
8M |
Packing Dimension |
27*27*10CM |
Weight |
0.15kg |
Technical Parameters
Thread length: Reverse thread
Linear Measurement Range: 2 mm (80 mils)
Initial Air Gap: 0.5 mm (20 mils)
Minimum Shaft Diameter: 25 mm (0.79”)
Target Material (Ferromagnetic Steel) :42CrMo4 (AISI/SAE 4140) Standard Other (On Request)
Protection Class: IP66, IEC 60529
Operating Temperature Range: Sensor incl. 1m Cable: -35 to +180°C (-31 to 356°F) Cable & Connector: -35 to +150°C (-31 to 302°F)
Material: Sensor Tip (PEEK Polyether Ether Ketone), Case (Stainless Steel) Cable (PTFE Polytetrafluoroethylene), Connector (Brass, nickel-plated)
Compatible Systems & Accessories
The EPRO PR6423/00R-031 integrates seamlessly with critical monitoring infrastructure:
MMS 6000 Protection Systems: Designed for turbine monitoring, this sensor pairs with modules like MMS6210 to provide real-time data on rotor dynamics.
CON021 Interface: Use the EPRO PR6423/00R-031 with CON021-compatible preamplifiers for signal conditioning and noise reduction, ensuring accurate measurements in high-electromagnetic-interference environments.
Typical Applications
The EPRO PR6423/00R-031 excels in diverse industrial scenarios:
Axial Displacement Monitoring: In power plants, it detects micron-level shifts in turbine shafts to prevent catastrophic rotor-stator collisions.
Bearing Health Assessment: For oil and gas compressors, the EPRO PR6423/00R-031 measures bearing wear and oil film thickness, enabling predictive maintenance and reducing unplanned downtime.
Installation & Maintenance Guidelines
Optimize performance with proper handling of the EPRO PR6423/00R-031:
Mounting: Secure the sensor using M10×1 or 3/8”-24-UNF-2A threads, ensuring a nominal gap of 1.5 mm (±0.2 mm) from the target surface. Calibrate using the factory-set linearity (pre-configured for 42CrMo4 steel) to achieve a -12 VDC output at the midpoint.
Troubleshooting: Regularly inspect cable integrity and connector seals. If signal drift occurs, verify the gap voltage and recalibrate using CON021-compatible test equipment. Replace worn cables or damaged LEMO connectors to maintain IP67-rated protection.
We also supply other models of this products: PR6423/000-031. They are the same in specifications, features and application range. The difference is the length of the thread, refer to the table for details.
Module Number |
Thread Length |
PR6423/00R-031 |
Reverse thread |
PR6423/000-031 |
25mm |