GE IC660BBD110
  • GE IC660BBD110GE IC660BBD110
  • GE IC660BBD110GE IC660BBD110
  • GE IC660BBD110GE IC660BBD110

GE IC660BBD110

Brand: GE
Description: 115 VAC 16 Circuit Discrete Input Module
Condition: Brand New
Certificate:COO TEST REPORT WARRANTY LETTER
Warranty: 1 year
Inventory Qty: 5
Payment Term: T/T
Shipping Port: ShenZhen
GE IC660BBD110 is a Genius I/O discrete input module designed to interface with 115V AC discrete input sensors, providing configurable broken wire and short circuit fault detection for enhanced diagnostic capabilities.

Send Inquiry

Product Description

Manufacture
GE
Model Number
IC660BBD110
Ordering Number
IC660BBD110
Catalog
-
Country Of Origin
USA
HS CODE
8538900000
Dimension
22.5cm*8.5cm*10cm
Packing Dimension
24cm*10cm*12cm
Weight
1.8kg

Operating Parameters

Detecting frequency: Operating frequency should be above 50 Hz and below 63 Hz.

Input Configuration: 2-wire and 3-wire proximity switch inputs, selectable on/off thresholds configurable from 25% to 85% of the input line voltage (per 8 inputs).

Diagnostics: Enhanced diagnostics, with selectable open and short circuit detection, are available to improve system reliability.


Product Features

Durability: GE IC660BBD110 is Well-engineered, built from quality materials with shock and vibration resistance, and environmental contaminants. As such, it is ideal for demanding industrial applications, whether on the factory floor or in outdoor control cabinets.

Cutting-Edge Signal Processing: Our advanced system allows for the expert processing of both analog and digital signals. GE IC660BBD110 includes integrated filters to eliminate noise and interference.


Installation

Mounting: You can mount it on a din rail with the supplied mounting clips. DIN rails must be cooled and established appropriately. It must be mounted securely so it does not move while the workpiece is being engaged.

Wiring: Connect as per the wiring diagram in the product manual. Wire the power supply, ensuring the polarity is correct. Use shielded cables to reduce interference for signal connections. Make sure all your wire connections are tight and insulated.

Configure: GE IC660BBD110 Once the device is in its final installation, the device should be configured for your application. This could include the various parameters for the communication, the input/output options, and any calibration values required. You need to use the specific software/ programming tools given by GE.


Application Ranges

Industrial Automation: The technology finds extensive usage in manufacturing plants to control machinery and equipment, precision and coordinate processes, manage factories, and numerous shop-floor activities. GE IC660BBD110 can connect with sensors and actuators to deliver functions including changing speeds of machines, regulating temperature, guaranteeing the finest quality of products, and so on.

Power Generation: GE IC660BBD110 is used for generator sets, turbines, and associated equipment in power plants for monitoring and controlling purposes. It collects data on voltage, current, temperature, and vibration, which makes maintenance predictor and improves power generation efficiency.

Oil & Gas Sector: Well site, refineries where it is used to perform various functions controlling and operational. It can measure pressure, flow rates, and chemical levels and activate alarms or corrective measures in the event of abnormal conditions.


Troubleshooting

Power Failure: If the device is not powering on, then check the power supply first. Check if the power cable is plugged in correctly and if the input voltage at the terminals is within the specified limits. Check the power supply unit for any issues. The only sign of life is the power indicator, which may – or may not – light up, in which case you have a blown fuse (if you have one). Inspect and replace the fuse, if necessary.

Communication Issues: If you are facing problems in data communication then examine the cable responsible for communication. Verify that they are properly connected and not damaged. Check the communication protocol settings on both GE IC660BBD110 and the attached device. There’s wheat and chaff, and the wheat can be lost or mangled.” If network connection is being used, you can also verify the network configuration and ping the device.

Damaged Signals: For the incorrect readings, first inspect the points of the signals. Check they are tightened up and soldered. Check out the calibration of the sensors and the device itself. If not calibrated correctly, inaccuracies can be caused in the readings.

If the device gets abnormally hot while in operation, see what the ambient temperature is. Verify that it is working in the specified operating range. Further, inspect whether anything is blocking the device’s cooling vents. If the issue continues, this indicates an internal breakdown in which serviceable parts are required on the device.




Hot Tags: GE, IC660BBD110, 115 VAC 16 Circuit Discrete Input Module

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept