GE IC695RMX128
  • GE IC695RMX128GE IC695RMX128
  • GE IC695RMX128GE IC695RMX128
  • GE IC695RMX128GE IC695RMX128

GE IC695RMX128

Brand: GE
Description: Redundancy Memory Xchange (RMX) Module
Condition: Brand New
Certificate:COO TEST REPORT WARRANTY LETTER
Warranty: 1 year
Inventory Qty: 7
Payment Term: T/T
Shipping Port: ShenZhen
GE IC695RMX128 enables efficient synchronization in industrial control systems, avoiding data issues. It also offers redundant backup, ensuring continuous system operation in case of module failure.

Send Inquiry

Product Description

Manufacture
GE
Model Number
IC695RMX128
Ordering Number
IC695RMX128
Catalog
RX3i
Country Of Origin
USA
HS CODE
85389091
Dimension
11.8cm x 7.2cm x 3.5cm
Packing Dimension
15cm x 10cm x 5cm
Weight
0.8kg

Operating Parameters

Memory Capacity: 128 MB.

Communication Interface: 2.12 Gbaud.

Power Requirements: 580 mA.

Operating Temperature Range: -40°C to +70°C.

Compatibility: Suitable for GE PACSystems RX3i controllers .


Product Features

Efficient Synchronization: In an industrial control system, various devices need to simultaneously work under the same clock reference to provide expressed control and type exchange. GE IC695RMX128 can effectively avoid data inconsistency and time drift and improve the overall stability and reliability of the system, enabling GE IC695RMX128 to easily sync clocks with other equipment.

pertinent to System that Despise a Higher Dependency—Redundancy: It has aRedundant backup capability in systems. Head to Head testing is with two modules of similar functionality, so if one of them fails, the standby will immediately take over the work, which can guarantee the continuous operation of the system and reduce failure downtime and loss.


Installation

Installing in the Rack : GE IC695RMX128 module is installed in the RX3i rack. Make certain that the module is properly and securely seated in the applicable slot and that connection is secure. The selection of the slot position should depend on the system configuration and requirements to ensure proper connection and communication with the other modules in the rack.

Fiber Optic Connection: The LC uplink fiber optic cables are plugged into the connectors of the module. When it comes to connecting everything, make sure that you have clean and unbroken fiber optic connectors, and that the fiber optic cables are being routed correctly and protected so as not to break or get pinched. To guarantee that the nodes are correctly linked to each other, the fiber optic cables should be connected according to the provided connection diagram and carefully follow the connection instructions.

Power Supply Cables: Connect the power supply cables based on the defined voltage and current. Make sure the polarity is correct, so it does not connected reversely; and supply voltage needs to be in the normal range. You will need a stable power supply to keep this module running accurately.


Troubleshooting

Fiber Optic Communication: In case of fiber optic communication failure, first check the connection of the fiber optic cables; it might be stuck or damaged. To check if the optical power is in the normal range, measure the optical power of the fiber optic cables with an optical power meter. Check the fiber optic transmitter and receiver modules and replace them if the optical power is abnormal.

Memory Exchange: In the event of a memory exchange error, check the configuration and connection of the redundant memory exchange modules (RMX).Make sure that the main and standby RMX are configured and connected properly. Verify the settings of the programming software for the memory exchange parameters to ensure the correct algo and functionality being used. If the memory exchange test is not conducted in a simulated environment, try to isolate the pathology as much as possible.

Network error detection failureIf the network error detection function fails, you should first check the network connection and configuration, ensure that the network is configured and connected normally. The network error detection settings in the programming software must be checked to verify that the parameters and thresholds for detection are accurate. If the issue still exists, then you can check if you are using the latest firmware for the module.


Application range

Industrial Automation: GE IC695RMX12 can handle data and control operations across redundant. in the manufacturing industry, like in automotive production lines, food processing lines and electronic equipment manufacturing. It guarantees the continuous operation of the production line, increases production efficiency and product quality, and reduces system failure-generated production interruptions and scrap rates.

Energy Management: The system stability and reliability is one of the most important aspects in power plants, substations and other energy production and distribution systems. In this context, the module may be utilized to control and synchronize multiple parallel control systems, ensuring that the power network operates safely and stably. If the control system has any faults, GE IC695RMX128 can promptly transfer to the standby system to keep away from blackouts and different mishaps.