Brand: GE Description: HF AC Supply Board Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 6 Payment Term: T/T Shipping Port: ShenZhen GE IS200HFPAG1ADC offers configurable CPU mode on power - up (Last, Stop, Run, with Last as default) for flexible startup. It also enables configurable Mod - bus address space mapping (Disabled or Standard) for seamless data transfer.
Manufacture |
GE |
Model Number |
IS200HFPAG1ADC |
Ordering Number |
IS200HFPAG1ADC |
Catalog |
Mark VI |
Country Of Origin |
USA |
HS CODE |
8479909090 |
Dimension |
38cm*12cm*5cm |
Packing Dimension |
40cm*14cm*7cm |
Weight |
1.2kg |
Operating Parameters
Power Supply Voltage: 24V.
Rated Current: 15A.
Mapping Of Modbus Address Space: Enabled / Conventional Modbus Addressing.
Compatible With: RX3i CPE305/CPE310/CPE330/CPE400 CPUs.
input signal range: -10 to 10 Volts.
Output Signal Range: 0V — 5V.
Temperature Range: -40°C to 85°C.
Product Features
Configurable CPU Mode on Power-up: GE IS200HFPAG1ADC enables users to configure the CPU mode during power-up that would take effect on the next power-up. They are Last, Stop, and Run. Default is Last, which means it will return to the mode it was under when it previously powered down. This offers flexibility in how the system starts up and runs, as users can adjust the device for their needs.
Configurable Mod-bus Address Space Mapping: This allows configurable Mod-bus address space mapping types for data transfer between Mod-bus TCP/IP clients and Ecosystems controllers. Disabled and Standard Mod-bus Addressing are the options. Set to Disabled if Ethernet firmware needs not Mod-bus TCP or Standard Modab Addressing, to allow a standard map to be used for transparent interconnect, enabling easy communication and data exchange between devices, infrastructure or even higher-level systems.
Installation
Install Tools: Use appropriate tools like screw drivers cost and cause of electrostatic Damage to the module Inspect GE IS200HFPAG1ADC module for physical damage. Make sure you also have the correct installation manual and relevant documentation available. Select the installation location The site has good heat dissipation conditions and is convenient for wiring and maintenance. Strong electromagnetic interference should be avoided, otherwise, the signal will be distorted and affect the module to work stably. Align the module with the mounting holes inside the control cabinet, and use screws to secure it firmly in place. It is intended that the module is installed in a flat and secure way to avoid any vibration or any kind of shifting histogram when using vectorial operations, possibly affecting its performance and reliability.
Troubleshooting
Power-up Issues: If GE IS200HFPAG1ADC does not power up properly, check the power supply first. Check that the power cable is properly secured in place, then confirm that the power source is providing a steady voltage. Check the configuration and ensure that other parameters or setting do not conflict with the expected mode of the module on power up.
Communication Issues: Check the communication cable connections as there may be a loose or damaged connection when communication issues exist. Module Modbus Address Space Mapping Settings be sure it matches the Modbus address space mapping settings of connected devices Furthermore, on the network configuration side, verify the communication protocol settings and see if there is any conflicts with other devices on the network. If you can, try using a different cable or port for the communication to isolate the issue manually.
USB Port Not Working : If the USB port is not working please initially check that the USB port is enabled in the settings for the module, this is a potential problem for RX3i CPE305/CPE310/CPE330/CPE400 CPUs Ensure that the removable data storage device connected is compatible and functional. Remove dust and debris from the USB port. This will confirm if the USB port is the issue, if it still remains defective, we might need to look into the module for a defect in hardware.
Application range
Steel Industry: In steel mills,GE IS200HFPAG1ADC is mainly used in the automation control system of steel rolling production lines. It can accurately control the speed and action of rolling mills and related equipment and exchange data with other control devices via the Modbus protocol to guarantee the quality and efficiency of steel production. Also used to monitor and control blast furnaces, it collects and transmits data such as temperature and pressure to enable operators to make timely adjustments.
Petrochemical Sector: GE IS200HFPAG1ADC is used in the process control system of petrochemical plants. This model & know-how can helpful for monitoring and controlling parameters like temperature, pressure, and flow rate in processes of oil refining and chemical production. Through its communication function, it can send the data back to the central control room in real-time, which will assist operators in monitoring and controlling the production process remotely and enable the safe, efficient production of the factory.