Brand: GE Description: Terminal Board Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 5 Payment Term: T/T Shipping Port: ShenZhen GE IS200STCIH2AED has multiple contact inputs with noise suppression, PC - based control compatibility, and adjustable excitation input ranges.
Manufacture |
GE |
Model Number |
IS200STCIH2AED |
Ordering Number |
IS200STCIH2AED |
Catalog |
- |
Country Of Origin |
USA |
HS CODE |
8479909090 |
Dimension |
14.5cm*9.5cm*4cm |
Packing Dimension |
18cm*13cm*7cm |
Weight |
0.8kg |
Operating Parameters
Number of Contact Inputs: 24.
Nominal Excitation Voltages: 24 V DC, 48 V DC, 125 V DC.
Excitation Voltage Input Ranges: 16 - 32 V DC.
Hardware Low-Pass Filter on Input: 4 ms.
Communication Interface: Ethernet.
Mounting Type: Din-rail or Flat mount.
Temperature range (for model) = - 20 °C - 50 °C.
Product Features
Multiple Contact Inputs and Noise Suppression: GE IS200STCIH2AED Accepts 24 contact inputs with nominal 24 V, 48V, or 125 V DC excitation (external) There are noise suppression mechanisms for every contact input. This area also provides protection from surges and HF noise allowing for a clean and stable flow so that the signals can be captured without confusion. Such noise suppression features, for example, allow the device to continue to operate normally and collect data reliably even in industrial environments rife with a broad range of electromagnetic interferences.
PC Based Control System of Induction Motor Submission 2: This board also works with the I/O pack. The 37-pin (female) D-type connector on the board allows for simple connection of the I/O pack. It then connects to the controller over Ethernet. With this compatibility and communication mode in place, integration into more extensive control systems is feasible, enabling efficient data transfer and control command execution between various components.
EXCITE INPUT RANGES ADJUSTABLE: Input excitation ranges for 24 V DC nominal excitation is 16 to 32 V DC input, for 48 V DC nominal excitation it is 32 to 64 V DC input, and for 125 V DC nominal excitation it is 100 to 145 V DC input. Adaptive to different power supply conditions in different industrial applications.
Installation
Din - rail Mounting: Start by making sure the power to the system is off. The board with a plastic insulator glides on the sheet metal carrier. Finally, slide the carrier onto the din-rail, ensuring that it is secured. Then use #18 AWG wires to attach the contact inputs to the terminal block. Tocanize shields on a different bracket. You know whatever has a small space and easy assemble and replace for example in Industrial control cabinet.
Flat Mounting: To flat mount, Fasten the board and the plastic insulator to a sheet metal assembly. Stake holes on the cupboard as per the mounting opening on the sheet metal get together. Finally, secured using bolts, insert the sheet metal assembly with the board into the cabinet. Connect contact inputs with the terminal block according to wiring requirements. GE IS200STCIH2AED allows for more stable installation for applications where vibration and shock are critical.
Troubleshooting
No Signal Input Detection: Inspect Wiring: Go over all of the wiring connections from the external sensors to the contact inputs on the top of the board. Make sure that the wires are in the best conditions and that they do not have loose, wrong or damaged connections. If there are any indications of problems, re-attach the wires tightly. It can also display any signs of corrosion on the connectors. Clean corroded connectors or replace damaged wires, as needed. If you see a frayed wire, definitely need to replace it, as GE IS200STCIH2AED can be the reason for no signal input detection.
Abnormal Signal Readings: Test Power Supply and Excitation Voltage: Ensure the power supply to the board is within the expected range. Check the voltage at the power input terminals with a voltmeter. And, verify that the excitation voltage is at an acceptable range of input excitation ranges. We learn on data until October 2023. Modify the power supply or verify that the external power source supplies the correct voltage.
I/O Pack Communication Failure: Verify Ethernet Cable and Configuration: Start by verifying the Ethernet cable linking the I/O pack to the board. Make sure the cable is intact and properly connected to the 37-pin D-type connector. And then check the Ethernet configuration on both the board and the I/O pack. Ensure IP addressing, sub-net mask, and RDP configurations match. Make any necessary adjustments so that the two are able to communicate effectively. For ex, if the IP addresses are not correctly set the I/O pack and the board will not be able to talk with each other.
Application range
Power Generation Plants: Transmission and gathering of signals from appropriate sensors often found in power generation plants; especially used in gas turbines and steam turbine powered ones. GE IS200STCIH2AED might receive signals from temperature sensors, pressure sensors, and vibration sensors which are installed on the turbines, for instance. The power generation is very sensitive; these readings are processed, and the control system works with it to help standardize the turbine to ensure stable power generation at the machine.
Industrial Automation Systems: When used in industrial automation systems, it can serve as a control system for production lines. It can be connected to sensors that monitor the position, movement and status of production equipment such as conveyor belts, robotic arms and motors.
Oil and Gas Industry: Where in Oil and Gas Industry it can be used in oil refineries and gas processing plants. For example, GE IS200STCIH2AEDcan be used to supervise and manage the operation of pumps, valves, and other devices. In an example, it can accept signals coming from flow sensors and pressure sensors installed in pipelines, and then proactively send control signals to open or close the valves that transport oil and gas safely and efficiently.