Brand: GE Description: Exciter Field Ground Detector Board Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 9 Payment Term: T/T Shipping Port: ShenZhen GE IS200EGDMH1AAB is a digital output module designed for use in power generation and turbine control systems. The module facilitates the control of external devices such as relays, actuators, and valves by providing multiple digital output channels.
Manufacture |
GE |
Model Number |
IS200EGDMH1AAB |
Ordering Number |
IS200EGDMH1AAB |
Catalog |
EX2100 |
Country Of Origin |
USA |
HS CODE |
8479909090 |
Dimension |
40cm*35cm*8cm |
Packing Dimension |
42cm*37cm*10cm |
Weight |
1.2kg |
Operating Parameters
Voltag nominal: 24 VDC (Current Direct)
Power Supply Voltage Range: 20 VDC ~ 30 VDC.
Power Consumption: 4W of power
Output Voltage: 24 VDC .
Digital output: 1A per .
Switch Speed: The switch speed of the digital outputs (depends on control system / load being switched) and is fast and fits most industrial automation applications.
Digital Inputs The module is intended to receive digital input signals (often ON/OFF, or 0V/24V signals).
Product Features
Intelligent Control Logic: GE IS200EGDMH1AAB uses the most sophisticated control algorithms to handle complex industrial processes.
Ingress Protection Rating: This module is rated IP20 which means the device is protected against solid objects greater than 12mm, but is not protected against water ingress. This makes it appropriate for placement in controlled and enclosed environments to prevent exposure to water or dust.
Short Circuit and Current Protection: Each output channel has its own short circuit and current protection, which effectively prevents damage from excessive flow or short circuit on the module and external devices.
Electrical Isolation: Digital outputs are electrically isolated from the control system to eliminate possible damage or interference due to electrical noise or ground loops.
Industrial Communication: GE IS200EGDMH1AAB module supports various communication protocols used in industrial settings, such as:
RTU Serial communication (Modbus RTU)ethernet/IPlt:highspeednetworkcommunication.
Bus Communication: GE IS200EGDMH1AAB communicates with the Mark VIe system through a communication bus, allowing it to send and receive signals and data from other components of the system.
Signal Degradation Prevention: The module separates its outputs from the control system to prevent signal degradation or damage from electrical noise.
Humidity: The module can function anywhere from 0% through 95% relative humidity (non-condensing).
Vibration Resistance: The GE IS200EGDMH1AAB is designed to resist vibration of 1G, making it suitable for use in environments where vibration is common, such as in power plants and manufacturing facilities.
Altitude: Module is designed for use at altitudes up to 2000 m (6561 ft) without noticeable reduction in performance.
Digital Outputs: The GE IS200EGDMH1AAB typically has a 10-20 ms cycle time for firing the digital outputs, enabling fast data transmission and real-time processing.
Fault diagnostics: Enhanced diagnostics capabilities allow operators to receive real-time information on module health and performance to help rapidly pinpoint issues like wiring faults or communication issues.
Application range
Power Generation: Utilized in turbine control systems to drive valves, relays, and other devices found in power stations.
Oil & Gas: Critical for actuators and relays in exploration, production and refining processes.
Industrial Automation: Applied in automated manufacturing systems controlling machinery, sensors, and safety systems.
Renewables: In the context of solar and wind farms, the module can control relays, disconnects, and other devices that are critical to energy production and system reliability.
Troubleshooting
Verify Power: Confirm that the module is getting a steady 24 VDC power supply.
Check the Wiring: Ensure the output is well connected to the external devices. On the other hand, a loose or faulty wiring can lead to an output failure.
Verify Output Channels: Make sure that the output channels are set correctly in the control system software.
LED Indicators: Look at the onboard diagnostic LEDs for fault codes.
Load Checking: The devices you are connecting shouldn't exceed the output current limit of 1A channel.