Brand: GE Description: InSync Bus Extender Card Condition: Brand New Certificate: COO TEST REPORT WARRANTY LETTER Warranty: 1 year Inventory Qty: 6 Payment Term: T/T Shipping Port: ShenZhen GE IS200ISBEH2ABC processes diverse analog and digital signals, ensures fast data communication, and provides robust self-monitoring and protection for stable, efficient system operation.
Manufacture |
GE |
Model Number |
IS200ISBEH2ABC |
Ordering Number |
IS200ISBEH2ABC |
Catalog |
Mark VI |
Country Of Origin |
USA |
HS CODE |
8479909090 |
Dimension |
40cm*30cm*10cm |
Packing Dimension |
42cm*32cm*12cm |
Weight |
1.2kg |
Operating Parameters
Input Voltage: 24V DC.
Output Voltage: 0 - 10V DC.
Output Current: 4 - 20mA.
protocols of communication: RS485, Modbus
Tk and runing at rate:9600bps.
Temp Range: -40C to 85C.
Product Feature
Ability to Process Different Signals: GE IS200ISBEH2ABC can process different types of signals. It is capable of high-precision acquisition of analog signals in various forms such as voltage and current, while also adept at processing digital signals of different types. It allows interfacing with all types of devices and systems utilizing different signal types to be able to integrate with and exchange data.
Fast Data Communication: GE IS200ISBEH2ABC has a high-speed data communication function to transmit data in the system quickly. This enables efficient data exchange with the other devices part of the architecture. It achieves fast data interaction between complex industrial network environments with lower transmission delay and higher comprehensive efficiency.
Strong Monitoring and Protections: Powerful tracking and defense. It is capable of self-monitoring at run-time — of its power supply, temperature, signal quality, etc. It will take immediate protection measures to avoid damaging the device when abnormal conditions such as over-voltage, over-current, and overheating are detected, and it will ensure the stability and reliability of the system.
Installation
Installation on DIN Rail: First, mount and properly attach the DIN rail. Next, position the device's mounting holes over the DIN rail and fasten it in place with the use of screws or clips. While mounting the device, don't forget to make sure tightly attached with DIN Rail otherwise it will shake around, lose or pop up and won't work properly. Cut a hole in the control panel that is the same size as the device. This needs to be inserted from the front side of the panel into the hole and secured with nuts or other fixing devices on the rear side. Throughout the installation process, ensure that the device is installed into a flat and flush position with the slab, as gaps or misalignment may lead to interference or impact the device's functionality.
Troubleshooting
Communication Failure: Communication cable and connection problem, first check blade cable plug is in place damage, weak contact. Next, check that the communication settings of the given device and the attached equipment are matched and configured properly together regarding communication protocol, baud rate, etc. Restart the communication device or reset the communication parameters if required.
Signal Abnormality: Abnormal input or output signals indicate that the signal source is not working properly, and the output of the signal source cannot be within the normal range. Check the signal cable if it is broken short-circuited or ensures there is no interference. In this case, the problem might occur due to the misfunction of the signal processing module of your device. Also, try swapping out the module or checkits internals.
Overheating Problem: When the device is overheating, first check the ventilation of the installation environment. Ensure nothing is blocking the DHCP around the appliance which might prevent heat dissipation. Ensure that the device is not over-laden or experiencing any abnormal operation causing excess heat. If possible, de-load the device or improve the heat transfer conditions. If this doesn't resolve the overheating issue, then there might be a fault with the device's cooling system or internal parts, which may need repair or replacement.
Application range
Power Industry: GE IS200ISBEH2ABC is used to control power generation equipment in power plants as well as in grid monitoring systems. In thermal power plants, for example, it can be used to monitor and control the operation of turbines and generators, collecting and processing the data of temperature, pressure, and rotation speed to ensure the safe and stable operation of power generation equipment. It can be applied for online monitoring of voltage/current/power parameters in power grid systems, enabling the grid to maintain stable and reliable operation.
It monopolizes industrial automation production line: GE IS200ISBEH2ABC can be used in the automotive manufacturing industry to control robotic arms for precise operations such as welding and assembly, as well as coordinate the operation of conveyor belts to improve production efficiency and product quality. In the electronics manufacturing industry, it can be applied to semiconductor manufacturing equipment, such as semiconductor chip lithography and packaging equipment control, to ensure the accuracy and stability of the production process.
Building Automation Systems: Such systems in buildings, building energy management, building environmental control, etc. The system can monitor and control parameters such as indoor temperature, humidity, lighting and air conditioning, realizing intelligent control of building environment, improving energy efficiency, providing users with a comfortable and safe environment.