Band: HIMA Description: Communications Processors Condition:New Certificate:COO TEST REPORT WARRANTY LETTER Warranty:1 year Inventory Qty: 8 Payment term:T/T Shipping Port:ShenZhen HIMA F8623B has stable electrical characteristics, provides certain storage capacity, supports multiple input and output interfaces, adopts redundant circuit architecture, supports multiple communication protocols, facilitates signal transmission, has high reliability, good security, strong anti-interference ability, and is easy to install, debug and maintain.
Manufacture |
HIMA |
Model Number |
F8623B |
Ordering Number |
981862361 |
Catalog |
HIMatrix |
Country Of Origin |
Germany |
HS CODE |
8536419090 |
Dimension |
16.3*3.8*5.8cm |
Packing Dimension |
20*6*8cm |
Weight |
0.4kg |
Technical Specifications
Computing and Processing Power: HIMA F8623B is an advanced machine with multi-processing capabilities and a processing speed of up to [X] MIPS, which enables fast and error-free calculations when processing safety logic work or data capture and analysis tasks, while allowing it to respond quickly to file name conditions.
Memory Capacity and Type: Built-in DDR [X] large-capacity memory with a total available capacity of up to [memory capacity value] GB can efficiently store programs and temporary data during runtime. It also includes [flash capacity value] GB of non-volatile flash memory to retain system configurations, safety programs and important historical data entries for a long time, thereby ensuring data autonomy and integrity.
Input and output interface: HIMA F8623B provides a rich digital input and output interface, including [X] digital input channels, supporting multiple mainstream voltage standards such as 24V DC; [X] digital output channels, sufficient to drive various external drive simulator actuators. In addition, it also has [X] high-precision analog input channels with a resolution of up to [X] bits, and [X] analog output channels, which can be used for monitoring and control of continuously changing physical quantities.
Functional characteristics
Safety control logic: HIMA F8623B customized flexible complexity is an industrial control function that allows users to quickly monitor numerous sensor signals in real time through detailed preset logic. When dangerous equipment fails, process parameters exceed the limit, etc., it will initiate an emergency shutdown, cut off the supply of dangerous media, etc. to ensure the safety of personnel, equipment and environment.
Redundancy and reliability design: HIMA F8623B adopts a dual redundant architecture, which not only includes redundant processing, but also redundant power supply modules and communication links. When the main components fail, seamless switching ensures redundancy, allowing continued operation. The overall reliability is better than [X]%, effectively reducing the production downtime caused by the failure of equipment to be used normally.
Communication and integration capabilities: Supports a variety of mainstream industrial communication protocols such as Profibus-DP and Modbus TCP. It can be easily integrated and linked with other industrial automation equipment, host computer monitoring systems, and distributed control systems to achieve all-round monitoring and coordinated operation of industrial production processes.
Installation and debugging
Installation environment: HIMA F8623B should be installed in an industrial control cabinet with good ventilation, suitable temperature and humidity (temperature range: [minimum temperature]-[maximum temperature] relative humidity: [minimum humidity]-[maximum humidity]), and low electromagnetic interference.
Installation process: Firmly install it on the cabinet rail, and then connect the power line, input and output signal line, and communication line according to the electrical schematic diagram to ensure that each line is firm to reduce the risk of short circuit or open circuit.
During the test process: Professional debugging application software initializes each device, sets communication parameters, input and output channel parameters, safety programming, and downloads safety logic programs. Test and even simulate various input signals and operating conditions to truly understand the function of the equipment - check whether the safety action fails, whether the data is collected or transmitted correctly, and if problems are found, make the best adjustments to operate until all equipment meets the safety control requirements on site.
Maintenance and Care: Routine inspections Check the bearing equipment that may be damaged once a month, check whether the equipment housing is damaged, whether the cooling fan is working properly, and finally check whether the lighting is working properly. Check the connection of the terminal blocks once every two months or twice a quarter to ensure that there is no looseness. Cleaning and maintenance methods - Clean the inside of the equipment with compressed air or a soft brush and hot air every six months to remove dust and dirt to ensure that the equipment has good heat dissipation performance; at the same time wipe the outer surface of the equipment to keep the equipment clean. Firmware upgrade - depends on the firmware update received from HIMA through the HIMA official website.