HIMA F8652X
  • HIMA F8652XHIMA F8652X
  • HIMA F8652XHIMA F8652X
  • HIMA F8652XHIMA F8652X
  • HIMA F8652XHIMA F8652X

HIMA F8652X

Brand: HIMA
Description:HIMA F8652X Central module
Condition:New
Certificate:COO TEST REPORT WARRANTY LETTER
Warranty:1 year
Inventory Qty:8
Payment term:T/T
Shipping Port:ShenZhen
HIMA F8652X has stable electrical characteristics, provides certain storage capacity, supports multiple input and output interfaces, adopts redundant circuit architecture, supports multiple communication protocols, facilitates signal transmission, has high reliability, good security, strong anti-interference ability, and is easy to install, debug and maintain.

Send Inquiry

Product Description

Manufacture
HIMA
Model Number
F8652X
Ordering Number
F8652X
Catalog
HIQUAD
Country Of Origin
United States (US)
HS CODE
8517795000
Dimension
16*16*12cm
Packing Dimension
18*18*15cm
Weight
0.6kg

Technical Specifications 

Processing Power

HIMA F8652X has a very powerful dedicated processor with a computing speed of [X] MIPS. 

HIMA F8652X has a high-speed DDR [X] large-capacity storage unit with [memory capacity value] GB, which ensures fast reading and writing of data while the system completes process operations. 

Input and output interface

Digital input: HIMA F8652X has [number of digital input channels] channels, supports multiple voltage formats (such as 24DC, 110AC, etc.), and accurately collects various switch signals on site, such as equipment start and stop, valve switch position, etc.

Digital output: It has [number of digital output channels] output channels, which can drive various actuators such as relays and solenoid valves, and accurately control various external devices such as emergency shutdown devices and alarm devices.

Analog input: HIMA F8652X has [number of analog input channels] high-precision analog input channels, with a sampling resolution of up to [X] bits, which can accurately monitor continuously changing physical quantities such as temperature, pressure, flow, and liquid level, providing accurate basis for safety control data.

Analog output: HIMA F8652X has [number of analog output channels] analog output channels, which can provide stable and accurate analog control signals for adjusting industrial parameters such as valve position and motor speed.


Functional features Safety logic function

Users can use professional programming software to easily customize complex and strict safety logic according to the specific safety requirements of the industrial site. The device monitors various input signals of sensors and field equipment in real time, and quickly determines whether there are dangerous situations according to the predetermined logic. 

HIMA F8652X adopts an advanced redundant architecture, including dual redundant processors, dual redundant power supply modules, and redundant communication links. When the host fails, the redundant components can automatically switch seamlessly to ensure the uninterrupted and orderly operation of the entire system. 

Communication and network functions: The system supports a variety of mainstream industrial communication protocols, including but not limited to Profibus-DP, Modbus TCP, Ethernet/IP, etc., and can be easily integrated with other industrial automation equipment, upper monitoring systems or distributed control systems to ensure smooth data transmission and integration. 


Installation and commissioning

Installation environment requirements: HIMA F8652X is best installed in an industrial control room or electric control cabinet at normal temperature. Usually the temperature must be between -20 and +60 degrees Celsius.

Debugging process: The equipment should be fully debugged. First, the power should be turned on, and the configuration of the equipment should be initialized using appropriately made professional debugging software. Configure the network parameters of the device, including IP address, subnet mask and gateway, and set the input and output channel parameters, including signal type, range and filter settings. Next, download the pre-designed safety logic program to the device and further conduct a comprehensive logic function test. 

Firmware upgrades: Pay close attention to any firmware updates announced by HIMA and upgrade the equipment regularly according to the specified operating procedures. Upgrading has the advantages of optimizing performance, introducing new features, and fixing security vulnerabilities.

When the device fault alarm is activated, its details must be recorded immediately, including its fault code, alarm time, and the relevant status of the device. Based on these fault records, refer to the device fault diagnosis manual for a rough check to investigate the possible causes of the fault, such as or attributed to hardware failure (CPU, memory, interface chip, etc.), software problems (safety logic program errors, improper communication protocol configuration, etc.) or external factors (power supply problems, signal interference, etc.). 